Technical Data
Type 2012
7.4 Operating conditions
7.4.1 Temperature ranges
Actuator
size
[mm]
Actuator
material
Temperature ranges
Medium (for PTFE
seal)
Environment
1)
40 - 63 PA –10 ... see “Fig. 5” –10 ... see “Fig. 5”
80 - 125 PA –10 ... +180 °C –10 ... +60 °C
40 - 80 PPS –10 ... +180 °C +5 ... +140 °C
100 - 125 PPS –10 ... +180 °C +5 ... +90 °C
2)
Tab. 1: Temperature ranges
1) If a pilot valve is used, the max. ambient temperature is + 55 °C.
Medium
temperature [°C]
Ambient
temperature
[°C]
100 120 140 160 180 200
70
60
50
40
30
20
63
50
40
Fig. 5: Temperature range of the maximum medium and ambient
temperature for PA actuators
2) briefly up to max. +140 °C
7.4.2 Pressure ranges
Actuator
material
Actuator size
[mm]
Max. pilot pressure
[bar]
PA
40 - 100 10
125 7
PPS
40 - 100 10
125 7
Tab. 2: Maximum pilot pressure
Medium and pilot pressure for control function A, flow direction
below the seat (standard)
Ori-
fice
Maximum medium pressure / Minimum pilot pressure
Actuator size ø [mm]
40 50 63 80 100 125
10/15 15/4.0 16/3.9
20 6.5/4.0 11/3.9 16/4.5
25 5.2/3.9 11/4.5 16/5.0
32 6/4.5 14/5.0 16/4.4
40 4/4.5 9/5.0 12.5/4.4 16/3.2
50 2.5/4.5 6/5.0 7.2/4.4 10/3.2
65 12/5.6
Tab. 3: Medium and pilot pressure for CFA, standard
english
Page view 9
1 2 ... 5 6 7 8 9 10 11 12 13 14 15 ... 69 70

Comments to this Manuals