SENSOR FOR ELECTROMAGNETIC FLOW METER – MANUAL
5
ESENS_FULLBORE_05.doc
OPERATING TEMPERATURES
o Shrewdness and precautions
NO YES
EBONITE LINING PP LINING PTFE LINING
Liquid Temp.
Ambient
Temp.
Liquid Temp.
Ambient
Temp.
Liquid Temp.
Ambient
Temp.
Min. Max Min. Max Min. Max Min. Max Min. Max Min. Max
° C 0 80 -5 60 0 60 0 60 -20 130 -10 60
° F 30 176 23 140 32 140 32 140 -4 266 14 140
LONG PIPE
3 X DN
2 X DN
NTI VIBRATION JOINTS
GASKET THICKNESS + 4mm
For installations on lon
pipes, please use the
anti vibration joints
For vertical installations is
preferable an ascendin
flow
Before ti
htenin
the nuts,
place both the flan
es of pipe
and device as near to
ether
as possible.
Durin
operation, the pipe
must be either completely full
of liquid, or completely empty
Install the sensor at a min.
distance to bows in pipes and
hydraulic accessories
For vertical installations with
descending flow direction
contact the manufacturer
void operatin
when the
pipe is partially empty
void the installation next to
bows in pipes and respect
min. inlet and outlet sections
Avoid the approach of the
flan
e and counter flan
e
usin
the closin
force o
the nuts
void the installation of the
sensor in a lon
pipe,
without an
support of the
same
LONG PIPE