6
Assembly
Type 2000 INOX
6. ASSEMBLY
DANGER!
Risk of injury from high pressure in the system!
• Turn off the pressure and vent the lines before loosening lines
or valves.
WARNING!
Risk of injury from improper assembly!
• Installation must only be carried out by authorized technicians
and with the appropriate tools!
Risk of injury from unintentional activation of the system and
uncontrolled restart!
• Secure system from unintentional activation.
• Following assembly, ensure a controlled restart.
Risk of crushing from moving pneumatic connection!
• When opening and closing the device, do not touch the moving
pneumatic connection.
• Do not reach into the area immediately above and below the
control air connection.
6.1. Preparatory work
→ Before connecting the valve, ensure the pipelines are flush
(stress-free).
→ Clean pipelines (sealing material, swarf, etc.).
Devices with welded body:
Remove the actuator from the valve body:
→ Clamp the valve body into a holding fixture.
NOTE!
Damage to the seat seal or the seat contour!
→ Open the valve for control functions A: Pressurize the lower
pilot air port with compressed air (5 bar).
→ Place a suitable open-end wrench on the wrench flat of the nipple.
→ Unscrew the actuator off the valve body.
Devices with threaded body:
→ Only disassemble the actuator if required by the customer.
6.2. Installation
6.2.1. Installing valve housing in pipeline
For welded housings:
→ Weld valve housing in pipeline system.
→ Check graphite seal and, if required, replace.
Graphite seal
For other housing models:
→ Connect valve housing to pipeline.
english