Description
Type 8025 / 8035
5. DESCRIPTION
5.1. Area of application
The compact version of the flowmeter type 8025 or 8035 is designed to measure the flow rate of a liquid and to totalise the
volume of a liquid.
The remote version of the flowmeter type 8025 is a transmitter that must be connected to an 8020 or an 8030 flow sensor with
a sinus or a pulse output, only in "Low Power" version.
5.2. General description
The 8025 is a flowmeter available in compact, panel or wall-mounted version. The 8035 is a flowmeter in compact version.
A compact version of the 8025 is composed of a flow sensor with paddle-wheel and of an electronic module (the electronic
is located in a housing with cover, display and 2 cable glands).
A compact version of the 8035 is composed of a sensor-fitting type S030, with paddle-wheel and of an electronic module
(the electronic is located in a housing with cover, display and 2 cable glands).
A panel version of the 8025 is an electronic module (an electronic located in an open housing with display).
A wall-mounted version of the 8025 is an electronic module (an electronic integrated in a housing with cover, display and 3
cable glands).
According to the version, the device requires a 12-36 V DC or a 115/230 V AC power supply.
The electrical connection is carried out via a male fixed connector or on the terminal blocks of the electronic board: whether
directly, whether via 2 or 3 cable glands.
5.3. Measuring principle
The circulation of fluid within the pipe causes the paddle wheel of the sensor to rotate. The flowmeter detects the rotation of
the paddle-wheel and generates a signal which frequency f is proportional to the flow rate Q, using the formula f = KxQ.
f = frequency in Hertz (Hz)
K = K factor of the S020 or S030 fitting used, in pulse/litre
Q = flow rate in litre/second
5.4. Available versions of the 8025 compact flowmeter
All the compact versions of the flowmeter 8025 have:
- a 4-20 mA current output;
- a pulse output ;
- two totalizers.
Supply voltage Seals Electrical connection Relays Sensor Order code
12-36 V DC FKM
1)
Male fixed connector - Hall, short
418762
12-36 V DC FKM
1)
- Hall, long
418763
12-36 V DC FKM
1)
Male fixed connector - Coil, short
418764
12-36 V DC FKM
1)
- Coil, long
418765
12-36 V DC FKM
1)
Terminal strips via 2 cable
glands
- Hall, short
418802
12-36 V DC FKM
1)
- Hall, long
418803
12-36 V DC FKM
1)
Terminal strips via 2 cable
glands
- Coil, short
418804
12-36 V DC FKM
1)
- Coil, long
418805
12-36 V DC FKM
1)
Terminal strips via 2 cable
glands
2 Hall, short
418778
12-36 V DC FKM
1)
2 Hall, long
418779
12-36 V DC FKM
1)
Terminal strips via 2 cable
glands
2 Coil, short
418780
12-36 V DC FKM
1)
2 Coil, long
418781
115/230 V AC FKM
1)
Terminal strips via 2 cable
glands
- Hall, short
418423
115/230 V AC FKM
1)
- Hall, long
418424
English
Page view 9
1 2 ... 5 6 7 8 9 10 11 12 13 14 15 ... 65 66

Comments to this Manuals

No comments